Single-use Disposable PPI Samplers are impaction-based samplers that provide a precise match to ISO 7708/CEN size-selection criteria that is specified in the 2016 OSHA final rule on respirable crystalline silica. All Disposable PPI Samplers contain pre-oiled impaction substrate that effectively trap larger particles for sample integrity. Disposable PPI Sampler models are offered for use at 2, 4, or 8 L/min and are available empty or preloaded.
Features
- Collection efficiency precisely matches ISO 7708/CEN criteria adopted in the OSHA final silica rule
- Single use means no cleaning or two-way shipping costs!
- Anti-static plastic
- Selection of flow rates available to meet specific applications
- 8 L/min respirable PPI: Enhances sensitivity (for short-term and/or low concentration sampling) using high flow pumps; ideal for new lower OSHA PEL for silica
- 4 L/min respirable PPI: Enhances sensitivity and can be used with personal pumps; TWA sampling for > 4 hours
- 2 L/min respirable PPI: 8-hour TWA sampling
- Disposable PPI Sampler Options
- Preloaded
- with filter preweighed by SKC
- with filter not preweighed
- Empty for filter loading by a laboratory or the user
- All disposable PPI Samplers are preloaded with pre-oiled impaction substrates in the inlet section
Reusable aluminum PPIs
are available
Performance published in Journal of Physics and referenced in the OSHA final silica rule
Specifications
Performance Profile
Sampling Rate |
2, 4, or 8 L/min |
Sample Pump |
AirChek Series for 2 and 4 L/min,
Leland Legacy for
8 L/min |
Sample Time |
Dependent on method used. Note: SKC tests indicate that a particulate mass of up to 6.8 mg on the four impaction substrates would not affect PPI performance. This amount is equivalent to sampling for 6 hours at 4 L/min in environments where respirable mass concentration is 4.76 mg/m3 and equals 50% of total dust. However, labs have reported to SKC that they prefer no more than 2 mg on the filter for analytical reasons. Therefore, SKC recommends that you work with your lab to determine optimum sample times for your unique sampling conditions. |
Sample Media |
37-mm, 5.0-µm PVC filter
Models with preweighed filter: filter preweighed at 70 F ± 3 F and 50% ± 5% relative humidity
Use cellulose pad or stainless steel screen for support.
|
Tubing |
1/4-in ID |
Impaction Substrate |
Four 3/8-in diameter pre-oiled porous plastic discs |
Analysis |
Gravimetric or chemical |
Body Material |
Conductive ABS plastic |
Dimensions |
Height: (clip to exhaust): 4.25 in
(10.8 cm)
Diameter: 1.8 in (4.6 cm)
Depth: 1.2 in (3.0 cm) |
Weight |
1.1 oz (31.2 gm) |
Shelf-life |
18 months from date of manufacture |
Order
Description |
Cat. No. |
Parallel Particle Impactor (PPI), Disposable, Respirable, Plastic, 8 L/min
Parallel Particle Impactor (PPI), plastic, single-use disposable, four stages, for respirable sampling at 8 L/min. The PPI provides the closest match to the entire ISO 7708/CEN respirable curve compared to any other sampler available, ea. Pre-assembled with four porous plastic disc impaction substrates Requires a 37-mm filter and support purchased separately |
225-384 |
Parallel Particle Impactor (PPI), Disposable, Preloaded, Respirable, Plastic, 8 L/min
Parallel Particle Impactor (PPI), plastic, disposable, four stages, for respirable sampling at 8 L/min. The PPI provides the closest match to the entire ISO 7708/CEN respirable curve compared to any other sampler available. Preloaded with four porous plastic disc impaction substrates, one 37-mm, 5.0-µm PVC collection filter, and one cellulose support, ea |
225-3841 |
Parallel Particle Impactor (PPI), Disposable, Respirable, Plastic, 2 L/min
Parallel Particle Impactor (PPI), plastic, single-use disposable, four-stage, for respirable sampling at 2 L/min. The PPI provides the closest match to the entire ISO 7708/CEN respirable curve, compared to any other sampler available. Pre-assembled with four porous plastic disc impaction substrates, ea Requires a 37-mm filter and support purchased separately, ea |
225-385 |
Parallel Particle Impactor (PPI), Disposable, Preloaded, Respirable, Plastic, 2 L/min
Parallel Particle Impactor (PPI), plastic, single-use disposable, four stages, for respirable sampling at 2 L/min. The PPI provides the closest match to the entire ISO 7708/CEN respirable curve compared to any other sampler available. Preloaded with four porous plastic disc impaction substrates, one 37-mm, 5.0-µm PVC collection filter, and one cellulose support, ea |
225-3851 |
Parallel Particle Impactor (PPI), Disposable, Respirable, Plastic, 4 L/min
Parallel Particle Impactor (PPI), plastic, single-use disposable, four stages, for respirable sampling at 4 L/min. The PPI provides the closest match to the entire ISO 7708/CEN respirable curve, compared to any other sampler available. Pre-assembled with four porous plastic disc impaction substrates, ea Requires a 37-mm filter and support purchased separately |
225-387 |
Parallel Particle Impactor (PPI), Disposable, Preloaded, Respirable, Plastic, 4 L/min
Parallel Particle Impactor (PPI), plastic, single-use disposable, four stages, for respirable sampling at 4 L/min. The PPI provides the closest match to the entire ISO 7708/CEN respirable curve compared to any other sampler available. Preloaded with four porous plastic disc impaction substrates, one 37-mm, 5.0-µm PVC collection filter, and one cellulose support, ea |
225-3871 |
Calibration Adapter for Disposable PPI
SKC Calibration Adapter for the Disposable Plastic Parallel Particle Impactor (PPI) |
225-389 |
Accessories
Description |
Cat. No. |
Stainless Steel Support Screen, 37 mm
Support Screen, 37 mm, stainless steel, wide mesh |
225-26 |
Cellulose Support Pad, pk/100
Support Pad, cellulose, 37 mm, pk/100 |
225-27 |
Calibration Adapter for Disposable PPI
SKC Calibration Adapter for the Disposable Plastic Parallel Particle Impactor (PPI) |
225-389 |
PVC Filters, 5.0 µm, 37 mm
PVC Filter, 5.0 µm, 37 mm, no support pad included, GLA-5000, pk/100 |
225-5-37 |
Filter-Keeper, 37 mm, with Labels
Filter-Keeper, 37-mm filter storage and archiving system with labels, pk/10 |
225-8303A |
Non-serrated Forceps, Stainless Steel
Forceps, stainless steel, non-serrated flat tips to prevent damage to filter membranes |
225-8371 |